Your browser doesn't support javascript.
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add filters

Database
Language
Document Type
Year range
1.
J Breath Res ; 17(3)2023 04 05.
Article in English | MEDLINE | ID: covidwho-2268981

ABSTRACT

Rapid testing is essential to fighting pandemics such as coronavirus disease 2019 (COVID-19), the disease caused by the severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2). Exhaled human breath contains multiple volatile molecules providing powerful potential for non-invasive diagnosis of diverse medical conditions. We investigated breath detection of SARS-CoV-2 infection using cavity-enhanced direct frequency comb spectroscopy (CE-DFCS), a state-of-the-art laser spectroscopic technique capable of a real-time massive collection of broadband molecular absorption features at ro-vibrational quantum state resolution and at parts-per-trillion volume detection sensitivity. Using a total of 170 individual breath samples (83 positive and 87 negative with SARS-CoV-2 based on reverse transcription polymerase chain reaction tests), we report excellent discrimination capability for SARS-CoV-2 infection with an area under the receiver-operating-characteristics curve of 0.849(4). Our results support the development of CE-DFCS as an alternative, rapid, non-invasive test for COVID-19 and highlight its remarkable potential for optical diagnoses of diverse biological conditions and disease states.


Subject(s)
COVID-19 , Humans , SARS-CoV-2 , Breath Tests , Spectrum Analysis , Lasers , Sensitivity and Specificity
2.
J Infect Dis ; 224(8): 1316-1324, 2021 10 28.
Article in English | MEDLINE | ID: covidwho-1493825

ABSTRACT

BACKGROUND: The coronavirus disease 2019 pandemic spread to >200 countries in <6 months. To understand coronavirus spread, determining transmission rate and defining factors that increase transmission risk are essential. Most cases are asymptomatic, but people with asymptomatic infection have viral loads indistinguishable from those in symptomatic people, and they do transmit severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2). However, asymptomatic cases are often undetected. METHODS: Given high residence hall student density, the University of Colorado Boulder established a mandatory weekly screening test program. We analyzed longitudinal data from 6408 students and identified 116 likely transmission events in which a second roommate tested positive within 14 days of the index roommate. RESULTS: Although the infection rate was lower in single-occupancy rooms (10%) than in multiple-occupancy rooms (19%), interroommate transmission occurred only about 20% of the time. Cases were usually asymptomatic at the time of detection. Notably, individuals who likely transmitted had an average viral load approximately 6.5-fold higher than individuals who did not (mean quantification cycle [Cq], 26.2 vs 28.9). Although students with diagnosed SARS-CoV-2 infection moved to isolation rooms, there was no difference in time to isolation between cases with or without interroommate transmission. CONCLUSIONS: This analysis argues that interroommate transmission occurs infrequently in residence halls and provides strong correlative evidence that viral load is proportional to transmission probability.


Subject(s)
Asymptomatic Infections/epidemiology , COVID-19/transmission , SARS-CoV-2/pathogenicity , Viral Load , COVID-19/diagnosis , COVID-19/epidemiology , COVID-19/virology , Humans , Pandemics/prevention & control , Pandemics/statistics & numerical data , SARS-CoV-2/isolation & purification , Students , Young Adult
3.
Water Res ; 204: 117613, 2021 Oct 01.
Article in English | MEDLINE | ID: covidwho-1373298

ABSTRACT

To assist in the COVID-19 public health guidance on a college campus, daily composite wastewater samples were withdrawn at 20 manhole locations across the University of Colorado Boulder campus. Low-cost autosamplers were fabricated in-house to enable an economical approach to this distributed study. These sample stations operated from August 25th until November 23rd during the fall 2020 semester, with 1512 samples collected. The concentration of SARS-CoV-2 in each sample was quantified through two comparative reverse transcription quantitative polymerase chain reactions (RT-qPCRs). These methods were distinct in the utilization of technical replicates and normalization to an endogenous control. (1) Higher temporal resolution compensates for supply chain or other constraints that prevent technical or biological replicates. (2) The data normalized by an endogenous control agreed with the raw concentration data, minimizing the utility of normalization. The raw wastewater concentration values reflected SARS-CoV-2 prevalence on campus as detected by clinical services. Overall, combining the low-cost composite sampler with a method that quantifies the SARS-CoV-2 signal within six hours enabled actionable and time-responsive data delivered to key stakeholders. With daily reporting of the findings, wastewater surveillance assisted in decision making during critical phases of the pandemic on campus, from detecting individual cases within populations ranging from 109 to 2048 individuals to monitoring the success of on-campus interventions.


Subject(s)
COVID-19 , SARS-CoV-2 , Humans , Pandemics , Universities , Wastewater
4.
Elife ; 102021 03 29.
Article in English | MEDLINE | ID: covidwho-1156211

ABSTRACT

Here, we develop a simple molecular test for SARS-CoV-2 in saliva based on reverse transcription loop-mediated isothermal amplification. The test has two steps: (1) heat saliva with a stabilization solution and (2) detect virus by incubating with a primer/enzyme mix. After incubation, saliva samples containing the SARS-CoV-2 genome turn bright yellow. Because this test is pH dependent, it can react falsely to some naturally acidic saliva samples. We report unique saliva stabilization protocols that rendered 295 healthy saliva samples compatible with the test, producing zero false positives. We also evaluated the test on 278 saliva samples from individuals who were infected with SARS-CoV-2 but had no symptoms at the time of saliva collection, and from 54 matched pairs of saliva and anterior nasal samples from infected individuals. The Saliva TwoStep test described herein identified infections with 94% sensitivity and >99% specificity in individuals with sub-clinical (asymptomatic or pre-symptomatic) infections.


Subject(s)
COVID-19/diagnosis , COVID-19/virology , Carrier State/diagnosis , Carrier State/virology , SARS-CoV-2/isolation & purification , Saliva/virology , COVID-19/metabolism , COVID-19 Testing , Humans , Molecular Diagnostic Techniques/methods , Nucleic Acid Amplification Techniques/methods , RNA, Viral/genetics , SARS-CoV-2/genetics , Sensitivity and Specificity , Specimen Handling/methods
SELECTION OF CITATIONS
SEARCH DETAIL